Technical Specifications

CleanAHull Ultrasonic Antifouling system is the most advanced, reliable and highest quality Ultrasonic Antifouling System available Worldwide. Manufactured in-house in our facility on the Gold Coast in Australia and shipped worldwide.View our detailed specifications below and feel free to contact us if you have any questions.

 



 

CleanAHull CLHUQ Ultrasonic Antifouling System

CleanAHull CLHUD Ultrasonic Antifouling System

 

Input: 12 or 24VDC Auto Selecting
Consumption: Average 960mA @ 12VDC
Standby Consumption: Average 15mA @ 12VDC

Input: 12 or 24VDC Auto Selecting
Consumption: Average 480mA @ 12VDC
Standby Consumption: Average 15mA @ 12VDC

 
  Consumption at 24VDC are typically 50 – 70% that of 12VDC values.



4 x Transducers + Footprints



2 x Transducers + Footprints

 
  • 1 x CLHUQ Control Module
  • 4 x CleanAHull Transducers (Model CLH-T50) 10m of cable each.
  • 4 x CleanAHull Transducer Footprints.
  • 1 x JB Weld Epoxy Kit
  • 1 x Loctite 515
  • 1 x Instruction / Installation Manual

 

  • 1 x CLHUQ Control Module
  • 2 x CleanAHull Transducers (Model CLH-T50) 10m of cable each.
  • 2 x CleanAHull Transducer Footprints.
  • 1 x JB Weld Epoxy Kit
  • 1 x Loctite 515
  • 1 x Instruction / Installation Manual

 

 

CleanAHull Certification FCC CE Ctick

 

4 Individually fused and protected transducer outputs.
50W peak output.

2 individually fused and protected transducer outputs.
50W peak output.

 
  • Internal Temperature control system with active compensation ensures system never exceeds operating range, increased life of electronics and optimal protection
  • Internal power monitoring
  • Onboard Monitoring and Isolation Function
  • Individual Fuses for each Channel (Transducers 1 & 2 and Transducers 3 & 4)
  • Sealed Enclosure (IP65) Dust Proof & Water Resistant
  • IP68 Transducers
  • Low Voltage Input
  • Ignition Protected
  • Transient Voltage Protection
  • High Quality Auto Switching 12-24V Input
  • High Temp Rated Fire Resistance Enclosure – up to 125°C (-40°C to +125°C)
 
  • Sleep Function: 3 or 6 Hour Sleep modes. Button on front panel of module. Press once to enable 3 hours sleep – Press twice to enable 6 hours. The unit will then countdown the timer on the LCD panel. When Sleep is operating the Status LED will flash slowly Blue Only. Transducer operation will cease until the countdown expires.
  • Error Notifications: Detailed Error status will be displayed using the LCD display. Buzzer will sound on Errors to attract attention to the problem.
  • Power Button: Main Power On/Off control
  • Active Self Monitoring: Internal Input and Output Current Monitoring, Temperature Monitoring and Active Output control ensures ultra long operating life and best possible Ultrasonic Protection.

Below is an outline of the core functions of the built in LCD display. Showing critical relevant information.



 

CleanAHull Brochure
CleanAHull Instruction Manual
CleanAHull Instruction Manual


 

 

    Enquire Today

    Name (required)

    Phone (required)

    Email (required)

    Message